<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="css/rss.xslt"?>
<rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:trackback="http://madskills.com/public/xml/rss/module/trackback/" xmlns:wfw="http://wellformedweb.org/CommentAPI/" xmlns:slash="http://purl.org/rss/1.0/modules/slash/"><channel><title>★安全可靠保密_超高成功率★ - 服务器维护</title><link>http://www.cdshuju.com/</link><description> - </description><generator>RainbowSoft Studio Z-Blog 1.8 Walle Build 100427</generator><language>zh-CN</language><copyright>Copyright 2006-2026 承德电脑硬盘维修数据恢复中心 Rights Reserved.</copyright><pubDate>Sun, 19 Apr 2026 23:32:36 +0800</pubDate><item><title>承德某单位戴尔R510服务器RAID失效导致的数据丢失维修案例</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/chengdeweixiudaierfuwuqi.html</link><pubDate>Mon, 18 Dec 2023 17:54:15 +0800</pubDate><guid>http://www.cdshuju.com/post/chengdeweixiudaierfuwuqi.html</guid><description><![CDATA[<p>&nbsp;承德某单位的一台戴尔R510服务器近期出现了RAID失效的问题，导致服务器无法正常工作，且数据丢失。为了尽快恢复服务器的正常运行并恢复数据，单位决定寻求承德电脑数据恢复中心进行专业的维修服务。</p><div>一、故障分析</div><div>在接收到客户请求后，我们立即与承德某单位联系，详细了解了服务器RAID失效的情况。经过初步分析，我们认为可能是由于RAID阵列配置错误或硬件故障导致的故障。为了进一步确定故障原因，我们决定对服务器进行详细检查。</div><div>二、修复过程</div><div>现场检测：我们派遣专业的工程师前往承德某单位现场，对服务器进行全面检测。通过专业的工具和设备，我们发现RAID阵列中的硬盘存在问题，导致RAID失效。</div><div>更换硬盘：针对问题硬盘，我们为客户提供了更换服务。在更换过程中，我们与客户保持了密切沟通，及时告知他修复的进展情况。</div><div>重新配置RAID：在更换硬盘后，我们对RAID阵列进行了重新配置。通过专业的工具和设备，我们重新设置了RAID级别和参数，确保服务器能够正常工作。</div><div>数据恢复：针对数据丢失的问题，我们尝试通过专业的数据恢复工具进行恢复。经过多次尝试，成功恢复了大部分丢失的数据。</div><div>测试与验证：在修复完成后，我们对服务器进行了全面测试，确保其正常运行且数据完整。同时，我们也与客户进行了沟通，告知他们修复的结果和后续操作建议。</div><div>三、总结与建议</div><div>&nbsp;</div><div>本次戴尔服务器RAID失效导致的数据丢失维修案例中，我们成功解决了客户遇到的问题，更换了问题硬盘并重新配置了RAID阵列，同时恢复了大部分丢失的数据。为了防止类似问题再次发生，我们建议客户定期对服务器进行维护和保养、加强服务器的安全防护措施、及时更新操作系统和应用程序等。同时，我们也为客户提供了一些建议和指导，帮助他们更好地管理和维护服务器。</div>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/chengdeweixiudaierfuwuqi.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1432</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1432&amp;key=367c7251</trackback:ping></item><item><title>承德宽城某单位IBM服务器数据恢复案例</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/1425.html</link><pubDate>Fri, 18 Aug 2023 17:04:53 +0800</pubDate><guid>http://www.cdshuju.com/post/1425.html</guid><description><![CDATA[<p>&nbsp; &nbsp; 承德宽城某单位IBM服务器存储重要的文件，服务器突然发生故障，所有分区的数据都无法读取，联系到了我们承德电脑数据恢复中心帮忙恢复。经检测，发现硬盘存在大量的物理坏道，这种情况只有使用PC3000等专业数据恢复设备才能够把数据拷贝出来。于是使用PC3000的DE功能对故障硬盘进行数据镜像，由于故障硬盘的坏道非常多，花费了两天时间才镜像完成，最终数据恢复98%，但客户已经对恢复结果非常满意了。#硬盘数据恢复</p>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/1425.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1425</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1425&amp;key=eb66ee7a</trackback:ping></item><item><title> 闪存介质不断普及，分布式存储建设如何选择存储介质？</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/1389.html</link><pubDate>Wed, 18 Apr 2018 17:31:37 +0800</pubDate><guid>http://www.cdshuju.com/post/1389.html</guid><description><![CDATA[<div><span style="font-size: medium;">&nbsp; &nbsp; 分布式架构的存储集群性能很大程度上取决于存储介质的有效选择。存储系统内部服务器如果有板载PCIe插槽，支持使用快速的SSD硬盘作为缓存来为HDD加速，或者直接采用全闪存架构。使用SSD作为缓存加速的场景下，通常建议一个SSD对应3~4块HDD。使用PCIe/NVMe SSD作为缓存加速的场景下，通常建议一个SSD对应8~10块HDD。<br /></span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">分布式存储在建设的时候，需要根据自身的需求和分布式存储软件的要求，进行介质搭配。</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">每一个厂商的分布式存储对存储介质都有着不同的要求，以VMware VSAN为例。</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">1、每个节点支持最多5个磁盘组</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">2、每个磁盘组最大8块硬盘，但是其中必须配置一块SSD，二期最多只能一块SSD。这块SSD用来做数据缓存，所有数据先写入到SSD，再写到磁盘组内其他硬盘。SSD的读操作占70%，写操作占30%。</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">3、VMware官方建议，SSD的容量为磁盘组内可用用量的10%。</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">4、根据以上原则，在建设分布式存储时，需要根据实际需要的容量进行存储介质的搭配规划。例如需要50TB容量，如果按照每个服务器配置8块硬盘计算，那么每个服务器需要配置1块800GB的SSD和7块1.2TB的SAS硬盘，一共配置7台服务器。</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">5、根据VSAN对SSD的需求作用，SSD需要配置混合型的SSD介质，满足SSD的读操作占70%，写操作占30%。要求。不要配置读取型和写入型的SSD。</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">闪存在分布式存储中起着举足轻重的作用：</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">1）日志盘</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">2）cache</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">3）数据存储</span></div><div><span style="font-size: medium;"><br /></span></div><div><span style="font-size: medium;">&nbsp; &nbsp; 但是，介于闪存高昂的价格，我们建议是根据自身的需求，性能的要求，来配置合理比例的SAS/SATA和SSD。SSD也有性能上的区分，例如sata ssd，和pcie ssd；也要根据实际的需要来进行选择。</span></div><div><span style="font-size: medium;"><span style="color: rgb(51, 51, 51); font-family: Tahoma, Geneva, sans-serif;">&nbsp; &nbsp; &nbsp;在</span><strong style="border: 0px; margin: 0px; padding: 0px; color: rgb(153, 0, 0); font-family: Tahoma, Geneva, sans-serif; font-size: 14px;">承德维修联想IBM戴尔HP服务器</strong><span style="color: rgb(51, 51, 51); font-family: Tahoma, Geneva, sans-serif;">，恢复故障硬盘中的重要数据，请联系我们！http://</span></span><a href="http://www.cdshuju.com/" style="border: 0px; margin: 0px; padding: 0px; color: rgb(153, 0, 0); font-family: Tahoma, Geneva, sans-serif; font-size: 14px;"><span style="font-size: medium;">www.cdshuju.com</span></a></div>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/1389.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1389</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1389&amp;key=9bb4fc95</trackback:ping></item><item><title>IBM 小型机P550更换内置RAID硬盘更换步骤</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/1385.html</link><pubDate>Wed, 28 Jun 2017 10:24:06 +0800</pubDate><guid>http://www.cdshuju.com/post/1385.html</guid><description><![CDATA[<p>&nbsp;IBM 小型机P550更换内置RAID硬盘更换步骤。</p><div>维护准备：</div><div>1．备件磁盘 00P2665</div><div>2．磁盘微码：Version 4335304B (C50K)</div><div>3．参考指南：PCI-X SCSI RAID controller Reference Guide for AIX</div><div>&nbsp;</div><div>维护步骤：（约需4.5小时）</div><div>1、检查系统和硬件设备：用命令lsdev &ndash;Cc pdisk、errpt查询硬盘设备信息。</div><div>2、用</div><div>diag-&gt;</div><div>Task selection -&gt;&nbsp;</div><div>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;RAID Array Manager -&gt;&nbsp;</div><div>PCI-X SCSI Disk Array Manager -&gt;</div><div>&nbsp; &nbsp; &nbsp; &nbsp; List PCI-X SCSI Disk Array configuration</div><div>检查raid信息和pdisk3 的状态。</div><div>&nbsp;</div><div>3、用以下操作再次确认硬盘槽位信息：</div><div>diag</div><div>Task Selection</div><div>RAID Array Manager&nbsp;</div><div>PCI-X SCSI Disk Array Manager</div><div>&nbsp; &nbsp;Diagnostics and Recovery Options</div><div>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;SCSI and SCSI RAID Hot Plug Manager</div><div>&nbsp; &nbsp; &nbsp; Identify a Device Attached to a SCSI Hot Swap Enclosure Device</div><div>选择对应的硬盘，按F7确认硬盘所在的槽位（磁盘的黄灯亮）</div><div>&nbsp;</div><div>4、做好rootvg备份（mksysb）和数据备份（强烈建议）。</div><div>&nbsp;</div><div>5、进行磁盘更换</div><div>用hot plug把硬盘更换，操作如下：</div><div>diag</div><div>Task Selection</div><div>RAID Array Manager&nbsp;</div><div>PCI-X SCSI Disk Array Manager</div><div>&nbsp; &nbsp;Diagnostics and Recovery Options</div><div>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;SCSI and SCSI RAID Hot Plug Manager</div><div>&nbsp; &nbsp; Replace/Remove a Device Attached to an SCSI Hot Swap Enclosure Device</div><div>把故障硬盘更换，然后按F3回到上一层菜单</div><div>&nbsp; &nbsp; &nbsp; &nbsp;SCSI and SCSI RAID Hot Plug Manager</div><div>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Configure Added/Replaced Devices</div><div>更换硬盘后，回到</div><div>diag-&gt;</div><div>Task selection -&gt;&nbsp;</div><div>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp;RAID Array Manager -&gt;&nbsp;</div><div>PCI-X SCSI Disk Array Manager -&gt;</div><div>&nbsp; &nbsp; &nbsp; &nbsp; List PCI-X SCSI Disk Array configuration</div><div>可以看到pdisk3的状态是failed，比如下图：</div><div>hdisk8 &nbsp; &nbsp; &nbsp;30-60-ff-0,2 &nbsp; &nbsp;Degraded &nbsp; &nbsp;Raid 10 Array &nbsp; &nbsp; 36.4 GB&nbsp;</div><div>pdisk2 &nbsp; &nbsp; &nbsp;30-60-00-10,0 &nbsp; &nbsp;Active &nbsp; &nbsp; Array Member &nbsp; &nbsp; 36.4GB&nbsp;</div><div>pdisk3 &nbsp; &nbsp; &nbsp;30-60-01-8,0 &nbsp; &nbsp; Failed &nbsp; &nbsp; Array Member &nbsp; &nbsp; 36.4GB&nbsp;</div><div>用lsdev &ndash;Cc pdisk是可以看到pdisk3是available，然后检查微码，如果磁盘微码：Version 4335304B以下的就必须升级，可更换上去的磁盘微码：Version &nbsp;4335304A，所以不需要升级微码。</div><div>&nbsp;</div><div>6、对RAID_1进行重建</div><div>diag-&gt;</div><div>Task selection -&gt;&nbsp;</div><div>&nbsp; &nbsp; &nbsp; &nbsp;RAID Array Manager -&gt;&nbsp;</div><div>PCI-X SCSI Disk Array Manager -&gt;</div><div>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Reconstruct a PCI-X SCSI Disk Array</div><div>选择新产生的磁盘进行重建(对146GB HDD大概需要4小时)</div><div>&nbsp;</div><div>7、重建完毕后，确认RAID_1的状态为optimal</div><div>diag-&gt;</div><div>&nbsp;Task selection -&gt;&nbsp;</div><div>&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; RAID Array Manager -&gt;&nbsp;</div><div>PCI-X SCSI Disk Array Manager -&gt;</div><div>&nbsp; &nbsp; &nbsp; &nbsp;List PCI-X SCSI Disk Array configuration</div>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/1385.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1385</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1385&amp;key=00528346</trackback:ping></item><item><title>承德滦平县某局联想万全T168服务器的数据恢复？</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/lianxiangfuwqit168.html</link><pubDate>Tue, 11 Aug 2015 22:24:06 +0800</pubDate><guid>http://www.cdshuju.com/post/lianxiangfuwqit168.html</guid><description><![CDATA[<p>&nbsp;&nbsp; 承德滦平县某局报修说，信息中心用的联想万全T168服务器,不能正常开启了，客户自己初步判断硬盘损坏。<br />【介质类型】:SATA服务器硬盘<br />【硬盘型号】:ST31000340NS<br />【硬盘容量】:1TBX3块<br />【检测恢复】:客户是承德滦平县某局机关,通过网上百度搜索承德服务器数据恢复找到本中心,客户报修说两块硬盘已经亮红灯识提示有问题了,工程师告诉提示他,停止任何操作,把服务器的硬盘拆下来带到承德数据恢复中心,联想万全T168服务器,硬盘是三块1TB的希捷企业级硬盘,一块为磁头轻微损伤,另外一块是希捷的固件门导致硬盘不能识别容量,显示为0MB，通过俄罗斯硬盘维修数据恢复设备PC3000 For UMDA把磁头损伤的那块做了一个全盘镜像到一个备用盘,再把固件有问题的修复,把三块硬盘通过重组阵列让数据重现,历时8个小时,经验证,服务器数据100%恢复成功.</p><p>注意事项：<br />&nbsp;&nbsp;&nbsp;&nbsp; 1、当服务器硬盘如出现异常，请马上断电，并迅速拨13091351084电话进行咨询，<strong>承德数据恢复</strong>中心的工程师会详细解答用户该如何处理。<br />&nbsp;&nbsp;&nbsp;&nbsp; 2、当发现介质读写速度很慢或读取不稳定，以免进一步造成二次破坏操作。<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 如果<strong>承德县、宽城县数据恢复、平泉县、兴隆县、丰宁县、围场县、滦平县、隆化县、承钢、双滦区、鹰手营子区的客户需要做数据恢复，或者在承德维修电脑硬盘恢复数据</strong>请联系我们<strong>承德数据恢复</strong>中心！<br />官网：<a href="http://www.cdshuju.com">www.cdshuju.com</a>&nbsp;&nbsp; QQ:54499258</p>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/lianxiangfuwqit168.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1358</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1358&amp;key=3032a17a</trackback:ping></item><item><title>  Novel系统的数据恢复情况有哪些？</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/Novel.html</link><pubDate>Sun, 09 Aug 2015 00:13:27 +0800</pubDate><guid>http://www.cdshuju.com/post/Novel.html</guid><description><![CDATA[<p>&nbsp;&nbsp; NOVELL系统分为NOVELL和Netware，文件系统为NSS和NWFS。<strong>承德数据修复</strong>中心可以帮您恢复NOVELL系统的故障。Novell是世界上知名网络系统公司，其主要产品NETWARE网络操作系统可将多台个人电脑连接到一个统一的整合了目录，存储，打印，数据库等的网络中。Novell旗下的其他产品包括，在欧洲流行的Linux操作系统 - SUSE， 网络管理软件 - Zenworks, 集成工具，文件目录服务产品等，目前世面上已很少有人使用。</p><p>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 1，从NOVELL或NETWARE损坏的卷或文件系统中恢复数据<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 2，从NOVELL或NETWARE重新分配过的卷中恢复数据<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 3，从压缩的NETWARE中恢复文件或目 录<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 4，从分段的卷中恢复数据<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 5，从损坏的卷或Vrepair失败的卷中恢复数据<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 6，支持IDE和SCSI<br />&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; 7，可恢复从NOVELL卷中删除的数据</p><p>&nbsp;&nbsp;&nbsp;&nbsp; 特别提示：您有重要数据在硬盘上，当出现数据丢失、硬盘损坏、文件无法读取的情况请立即关机并送修至<strong>承德电脑数据恢复</strong>中心。</p>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/Novel.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1357</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1357&amp;key=96fbb4f4</trackback:ping></item><item><title>我中心提供IBM服务器主板维修服务</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/1354.html</link><pubDate>Fri, 31 Jul 2015 11:15:29 +0800</pubDate><guid>http://www.cdshuju.com/post/1354.html</guid><description><![CDATA[<p>&nbsp;&nbsp;&nbsp; 本中心承诺提供最高效的服务器主板维修服务。通常家用PC的主板，更多的要求是在性能和功能上，而服务器主板是专门为满足服务器应用(高稳定性、高性能、高兼容性的环境)而开发的主机板。由于服务器的高运作时间，高运作强度，以及巨大的数据转换量，电源功耗量，I/O吞吐量，因此对服务器主板的要求是相当严格的，所以相对而言，服务器维修要求的技术也相对要求较高。</p><p>&nbsp;&nbsp; 通常而言，服务器主板维修只针对保外的服务器而言，保内的服务器我们还是推荐客户通过HP专业客服进行处理。我们的维修主要有以下几块：</p><p>服务器开机不能通电故障，开关按下机器无反应。<br />服务器开机后经常死机 某些元器件老化问题<br />服务器开机不显示，花屏 显卡BGA损坏<br />服务器开机不认硬盘 南桥电路 南桥BGA 硬盘接口电路 SCSI卡损坏<br />服务器开机能通电但无花面 主板供电电路或者功能芯片坏<br />&nbsp;</p>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/1354.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1354</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1354&amp;key=6f6f43b4</trackback:ping></item><item><title>承德某商贸公司联想服务器数据恢复其两块硬盘盘先后掉线</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/1351.html</link><pubDate>Tue, 28 Jul 2015 11:57:46 +0800</pubDate><guid>http://www.cdshuju.com/post/1351.html</guid><description><![CDATA[<p>&nbsp;客户名称：承德**商贸公司<br />硬盘型号：WD5000AAKX<br />故障描述：服务器上两块500G盘组的RAID1，昨天有块盘掉线了，于是就把坏盘抽出来，将好盘替换上去。在替换的过程中，另一块盘突然也掉线了，造成现在服务器无法启动。<br />恢复过程：经工程师检测两块盘都有物理坏道。于是工程师运用专业数据恢复设备PC3000-UDMA对硬盘进行镜像，随后运用自主研发的专业算法对镜像文件进行分析，并将数据提取出来。<br />恢复时间：3天<br />恢复结果：服务器数据恢复成功。<br />注明：因涉及到客户个人隐私，客户的部分信息我们将进行屏蔽处理！</p><p>&nbsp;&nbsp;&nbsp;&nbsp; 在承德维修服务器，恢复服务器数据请联系我们<a target="_blank" href="http://www.cdshuju.com/">承德数据恢复</a>中心！</p>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/1351.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1351</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1351&amp;key=6b9f808f</trackback:ping></item><item><title>IBM服务器数据安全方案简介</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/ibmfuwuqi1.html</link><pubDate>Tue, 21 Jul 2015 14:26:05 +0800</pubDate><guid>http://www.cdshuju.com/post/ibmfuwuqi1.html</guid><description><![CDATA[<p>&nbsp;&nbsp;&nbsp; 计算机的普及和应用，越来越多的企业开始关注企业数据的重要性，同时，越来越多的企业也开始认识到企业中最宝贵的不是各种网络硬件，而是网络中存储的业务数据。<a target="_blank" href="http://www.cdshuju.com/">承德维修服务器</a>时，数据安全也就显得更为重要。硬件的自然损坏、系统的崩溃、病毒的入侵、人为的操作失误，都会造成数据的丢失。数据一旦丢失，将会严重影响企业日常业务的正常运作&mdash;&mdash;丧失商业机会、客户表达不满、营业收入降低、企业声誉受损等，从而会带来一系列对企业的不良影响。因此，最关键是提供一个数据安全有效的解决方案，防范于未然，而不是在问题发生之后才去恢复数据，这样不但影响企业的正常运作而且还要花巨额费用。保证企业数据的安全，就是保证企业的安全，也就保证了企业的生命力。在现实生活中，企业数据的丢失从而导致企业遭受巨大损失甚至企业倒闭的事情也常有发生。因此，企业数据安全被提升到一个具有战略意义的地位，成为很多企业正常运行的基石。</p><p>根据公司的具体情况，数据安全的解决方案也有很大的区别，<a target="_blank" href="http://www.cdshuju.com/">承德数据恢复</a>中心归纳常用的有以下几种解决方案：</p><p>一、企业数据硬件解决方案<br />1.服务器的磁盘阵列（RAID）数据安全解决方案 <br />2.多台服务器的集群数据安全解决方案 <br />3.网络阵列柜数据安全解决方案 <br />4.网络硬件防火墙数据安全解决方案</p><p>二、企业数据软件上的解决方案<br />1.安装杀毒软件和防火墙 <br />2.企业内外网的解决 <br />3.用户访问级别的设定<br />&nbsp;</p><p>在承德维修服务器恢复电脑数据，在<a target="_blank" href="http://www.cdshuju.com/">承德维修电脑</a>联系我们！</p>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/ibmfuwuqi1.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1342</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1342&amp;key=a28539d1</trackback:ping></item><item><title>IBM服务器Raid卡维修与数据恢复解析</title><author>a@b.com (yyf)</author><link>http://www.cdshuju.com/post/1341.html</link><pubDate>Tue, 21 Jul 2015 09:20:18 +0800</pubDate><guid>http://www.cdshuju.com/post/1341.html</guid><description><![CDATA[<p>&nbsp;&nbsp;&nbsp; RAID卡就是用来实现RAID功能的板卡，通常是由I/O处理器、硬盘控制器、硬盘连接器和缓存等一系列零组件构成的。不同的RAID卡支持的RAID功能不同。支持RAlD0、RAID1、RAID3、RAID4、RAID5、RAID10不等。RAID卡可以让很多磁盘驱动器同时传输数据，而这些磁盘驱动器在逻辑上又是一个磁盘驱动器，所以使用RAID可以达到单个的磁盘驱动器几倍、几十倍甚至上百倍的速率。</p><p>&nbsp;&nbsp;&nbsp; RAID卡损坏不同于服务器别的部件损坏，由于它与硬盘都和服务器数据息息相关，所以一旦RIAD卡损坏，就就有可能造成服务器数据的丢失，特别是某些RAID卡，在其中存有部分RAID信息，一旦损坏，就算更换一块新的RAID卡，服务器的数据也无法正常使用。我中心的RAID卡维修则无此顾虑，公司自主研发的磁盘阵列恢复软件可以通过一系列的智能算法，恢复出存放在RAID卡中的RAID信息，保证在RAID卡维修或更换后服务器中的数据能够正常使用。</p><p>&nbsp;&nbsp;&nbsp; 在<a target="_blank" href="http://www.cdshuju.com/">承德维修IBM服务器</a>恢复数据可以联系我们！</p>]]></description><category>服务器维护</category><comments>http://www.cdshuju.com/post/1341.html#comment</comments><wfw:comment>http://www.cdshuju.com/</wfw:comment><wfw:commentRss>http://www.cdshuju.com/feed.asp?cmt=1341</wfw:commentRss><trackback:ping>http://www.cdshuju.com/cmd.asp?act=tb&amp;id=1341&amp;key=cc92ff95</trackback:ping></item></channel></rss>
